Publication
Optimal pressure sensor placement in water distribution networks minimizing leak location uncertainty
Conference Article
Conference
Computing and Control for the Water Industry Conference (CCWI)
Edition
13th
Pages
953–962
Doc link
http://dx.doi.org/10.1016/j.proeng.2015.08.979
File
Authors
-
Nejjari Akhi-Elarab, Fatiha
-
Sarrate Estruch, Ramon
-
Blesa Izquierdo, Joaquim
Projects associated
Abstract
In this paper an optimal sensor placement strategy based on pressure sensitivity matrix analysis and an exhaustive search strategy that maximizes some diagnosis specifications for a water distribution network is presented. An average worst leak expansion distance as a new leak location performance measure has been proposed. This metric is later used to assess the leak location uncertainty provided by a sensor configuration. The method is combined with a clustering technique in order to reduce the size and the complexity of the sensor placement problem. The strategy is successfully applied to determine the location of a set of pressure sensors in a district metered area in the Barcelona water distribution network.
Categories
automation.
Author keywords
clustering; leak location; sensor placement
Scientific reference
F. Nejjari, R. Sarrate and J. Blesa. Optimal pressure sensor placement in water distribution networks minimizing leak location uncertainty, 13th Computing and Control for the Water Industry Conference, 2015, Leicester, Vol 119 of Procedia Engineering, pp. 953–962, Elsevier.
Follow us!